泵不能启动
原因
1.泵粘死
2.泵油粘度过高
3.油泵磨损或外来物集聚
4.电机电压不符 5.连线错误 6.电机出错
1.拆泵修理
2.保持室温高于12℃或换油 3.更换损坏件或清理
4.更换电机
5.检查并修理线路
6.更换电机
排气速度太低
1.抽气与排气管直径太小或管长度太长 2.油被污染 3.主阀破损
4.进气口滤网被堵塞
5.泵油不对 6.真空系统泄漏 7.泵指标低于系统要求
1.更换成符合要求管线 2.更换泵油 3.更换主阀 4.清洗滤网 5.更换成要求泵油 6.修理泄漏处 7.更换成满足要求泵
Becker贝克真空泵常见故障及消除方法
真空度降低
原因:
1、系统漏气 2、油量不足 3、泵油污染严重|
4、排气阀片开裂或脱落 5、排气阀座上回油孔堵塞| 6、被抽气体温度过高 7、泵久用零件老化 8、泵密封件老化
消除方法:检漏、补漏 加油至规定要求 换新油 换排气阀片 疏通回油孔 气体冷却处理 更换磨损零件 更换密封件
喷油
原因: 1、油量过多 2、挡油盒、挡油板脱落 3、吸入压入长期偏高 消除方法:放油至规定要求 重新安装 更换大型号的泵